Re: SunFire v440
- From
- Mikhail Y Kuznetsov (2:5020/400)
- To
- Andrew Lutov"
- Date
- 2008-10-17T02:55:20Z
- Area
- RU.UNIX.SOLARIS
From: "Mikhail Y Kuznetsov" <CaHTeXHuK@63.RU>
"Andrew Lutov" <andrew_l @ newmail.ru> сообщил/сообщила в новостях
следующее: news:gcuff8$1i56$1@fxg.gcom.ru...
> Hello, All!
>
> Кожет кто подсказать про вот такое:
>
> Error : LSI 1030 : timeout waiting for interrupts status
> Could not set initiator ID
[skip]
мне вот помогала нота 207032
Symptoms
66RNQ3Y Internal ID use only.
'probe-scsi-all' may fail with the following error message (or similar).
{0} ok probe-scsi-all
This command may hang the system if a Stop-A or halt command
has been executed. Please type reset-all to reset the system
before executing this command.
Do you wish to continue? (y/n) y
/pci@1f,700000/scsi@2,1
ERROR: LSI1030: timeout waiting for interrupt status.ERROR: LSI1030: Could
not set initiator ID.ERROR: LSI1030: timeout waiting for interrupt
status.ERROR: LSI1030: Could not set initiator ID.
Can't open SCSI host adapter/pci@1f,700000/scsi@2
ERROR: LSI1030 MPT Firmware, Fault code: 8112: PCI bus fault
ERROR: LSI1030: Could not set initiator ID.ERROR: LSI1030 MPT Firmware,
Fault code: 8112: PCI bus fault
ERROR: LSI1030: Could not set initiator ID.
Can't open SCSI host adapter{0} ok
Resolution
24ZC28Y Internal ID use only.
Run 'reset-all' prior to run 'probe-scsi-all'.
ok reset-all
ok probe-scsi-allImportant Notes: If performing this recommendation when
troubleshooting a problem at OBP, verify the auto-boot? parameter is set to
false.
If set to true it is possible that the procedure could result in a reboot
loop condition that further complicates troubleshooting. Make sure and reset
this variable after troubleshooting has completed.
Product
Sun Fire V440 Server
--- ifmail v.2.15dev5.4
* Origin: Home Ltd. (2:5020/400)
SEEN-BY: 236/100 450/1024 5000/5000 5011/13 5012/46 5015/28 5019/40 5020/400
SEEN-BY: 5020/545 2238 4441 5021/29 5025/3 5030/1957 5035/38 5045/7 5054/1 4 8
SEEN-BY: 5054/9 28 37 5061/120 5062/10 5064/7 5080/68 5085/13 5095/20 5096/18
SEEN-BY: 6001/10
PATH: 5020/400 545 5054/1 37